Technical data
UL-HGX46/280 ML 33 CO2 T
Application | Refrigeration & AC |
Compressor refrigeration capacity | 64.60 kW |
Power consumption | 34.70 kW |
Current draw (460 V) | 51.30 A 1) |
Mass flow | 0.430 kg/s |
at following operating condition:
Refrigerant | R744 |
Reference temperature | Dew point |
Evaporating temperature | -10.0 °C |
High pressure (abs.) | 90.00 bar |
Gas cooler outlet temperature | 35.0 °C |
Supply frequency | 60 Hz |
Voltage | 460 V |
Suction gas superheat | 10 K |
Subcooling (outside cond.) | -- K |
Number of cylinders / Bore / Stroke | 6 / 1.42 inch / 1.81 inch |
Displacement 60 Hz (1740 rpm) | 1036 cfh |
Voltage 2) | 440-480V Y/YY -3- 60Hz PW |
Winding divided into | 50% / 50% |
Max. working current 3) | 59.3 A |
Max. power consumption 3) | 42.9 kW |
Starting current (rotor blocked) 3) | 170.0 / 275.0 A |
Motor protection | INT69 G |
Protection terminal box | IP 66 |
Weight | 512 lb |
Frequency range 4) | 20 -70 Hz |
Max. permissible overpressure (g) (LP/HP) 5) | 1450 / 2176 psi |
Connection suction line SV | 1 1/8 " |
Connection discharge line DV | 7/8 " |
Lubrication | Oil pump |
Oil type R744 | BOCKlub E85 |
Oil charge | 92 fl.oz |
Dimensions
Length / Width / Height | 30.46 / 18.34 / 15.85 inch |
Sound power level LWA 6) | 82 db(A) @ -10 °C / 15 °C / 10 K |
| 80 db(A) @ -10 °C / 90 bar / 10 K |
Sound pressure level LpA 6) | 68 db(A) @ -10 °C / 15 °C / 10 K |
| 67 db(A) @ -10 °C / 90 bar / 10 K |
Scope of supply
Semi-hermetic six-cylinder reciprocating compressor with drive motor
Single-section compressor housing with hermetically integrated electric motor
Winding protection with PTC resistor sensors and
electronic trigger unit INT69 G
115-230 V AC, 50/60 Hz,
IP00
Oil pump
Pressure relief valve suction and discharge line
Oil sump heater 110-120 V - 1 - 60 Hz, 160 W
Oil charge:
BOCKlub E85
Sight glass
Suction and discharge connection using blind flange
Inert gas charge
Accessories
Digital capacity regulator DCR22 CO2
flexxCO2NTROL
110 V -1- 50/60 Hz, 8W, IP65
incl. thermal
protection thermostat (PTC) on cylinder cover with DCR22 CO2
for
further information see 96590-DGbF
Compressor oil BOCKlub E85 as 1 liter refill
unit 7)
Compressor oil PAG (factory filling) 8)
Hot gas temperature sensor (Pt1000, for external
evaluation)
recommended for DCR22 CO2
flexxCO2NTROL
for further information see 96590-DGbF
Oil differential pressure sensor DELTA-P II 115-230 V - 1
- 50/60 Hz,
incl. oil pump prepared for oil differential pressure
sensor 7)
Thermal protection thermostat per cylinder cover
Oil temperature sensor (Pt1000, for external evaluation)
Suction and discharge line valve in soldering / welding
design
Suction and discharge line valve with cutting ring
connection for steel pipes
Intermediate adapter for discharge line valve 7)
Screw adapter for oil level regulator 7)
4 anti-vibration pads enclosed
Special voltage and/or frequency (on request)
Notes
1) | Value calculated. Deviation to reality possible. |
2) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values |
3) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. |
4) | The maximum permissible working current of the compressor
(Imax) must not be exceeded. Take account of the guidelines for use of frequency
inverter (see compressor assembly instruction or selection software).
|
5) | LP = Low
pressure HP = High pressure |
6) | Declared dual-number noise emission values are in
accordance with ISO 4871. The corresponding uncertainty to the sound power level
is KWA = 2,5 dB and to the sound pressure level is KpA =
2,5 dB. The values are valid for 50 Hz with the refrigerant R744 at the standard
rating points according to EN 12900.
- A-weighted sound power level LWA (re 1 pW), in decibel. To
determine the values, measurement methods of the ISO 3740 standard with
accuracy class 2 or higher were used.
- A-weighted sound pressure level LpA (re 20 µPa), in decibel.
The values are calculated from the sound power level in accordance with ISO
11203: LpA = LWA - Q2 at a distance of d = 1m
to the reference box.
|
7) | Enclosure |
8) | On request |