Technical data
UL-HGX88e/2400 ML 60
| Application | Refrigeration & AC |
| Compressor refrigeration capacity | 137.00 kW |
| Power consumption | 42.70 kW |
| Current draw (460 V) | 69.10 A 1) |
| Mass flow | 0.958 kg/s |
at following operating condition:
| Refrigerant | R134a |
| Reference temperature | Dew point |
| Evaporating temperature | 5.0 °C |
| Condensing temperature | 50.0 °C |
| Supply frequency | 60 Hz |
| Voltage | 460 V |
| Suction gas temperature | 20 °C |
| Subcooling (outside cond.) | 0 K |
| Number of cylinders / Bore / Stroke | 8 / 2.95 inch / 2.68 inch |
| Displacement 60 Hz (1740 rpm) | 8861 cfh |
| Voltage 2) | 440-480V Y/YY -3- 60Hz PW |
| Winding divided into | 50% / 50% |
| Max. working current 3) | 101.0 A |
| Max. power consumption 3) | 71.8 kW |
| Starting current (rotor blocked) 3) | 385.0 / 543.0 A |
| Motor protection | INT69 G |
| Protection terminal box | IP 65 |
| Weight | 1012 lb |
| Frequency range 4) | 25 - 60 Hz |
| Max. permissible overpressure (g) (LP/HP) 5) | 276 / 406 psi |
| Connection suction line SV | 3 1/8 " |
| Connection discharge line DV | 2 1/8 " |
| Lubrication | Oil pump |
| Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 |
| Oil charge | 338 fl.oz |
| Dimensions
Length / Width / Height | 37.13 / 25.51 / 25.83 inch |
| Sound power level LWA 6) | 89 dB(A) @ -35 °C / +40 °C |
| 86 dB(A) @ -10 °C / +45 °C |
| Sound pressure level LpA 6) | 76 dB(A) @ -35 °C / +40 °C |
| 72 dB(A) @ -10 °C / +45 °C |
Scope of supply
Semi-hermetic eight-cylinder reciprocating compressor with
drive motor
Single-section Compressor housing with hermetically integrated
electric motor
Winding protection with PTC resistor sensors and
electronic trigger unit INT69 G
115-230 V AC, 50/60 Hz,
IP00
Oil pump
Possibility of
connection of oil level controllers ESK, AC+R or CARLY
Oil pump cover with screw-in option for oil differential
pressure sensor DELTA-P II
Possibility of connection of oil level controllers Traxoil 7)
Oil charge:
BOCKlub E55
Three sight glasses
Pressure relief valve
Suction and discharge line valve
Inert gas charge
Notes
| 1) | Value calculated. Deviation to reality possible. |
| 2) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values
PW = part
winding, motors for part winding starting (no start unloaders required)
Designs for Y/D on request |
| 3) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. |
| 4) | The maximum permissible working current of the compressor
(Imax) must not be exceeded. Take account of the guidelines for use of frequency
inverter (see compressor assembly instruction or selection software).
|
| 5) | LP = Low
pressure HP = High pressure |
| 6) | Declared dual-number noise emission values are in
accordance with ISO 4871. The corresponding uncertainty to the sound power level
is KWA = 2,5 dB and to the sound pressure level is KpA =
2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the
standard rating points according to EN 12900.
- A-weighted sound power level LWA (re 1 pW), in decibel. To
determine the values, measurement methods of the ISO 3740 standard with
accuracy class 2 or higher were used .
- A-weighted sound pressure level LpA (re 20 µPa), in decibel.
The values are calculated from the sound power level in accordance with ISO
11203: LpA = LWA - Q2 at a distance of d = 1m
to the reference box.
|
| 7) | Only with additional
adapter possible |