Technical data
UL-HGX66e/1340 ML 31
Application | Refrigeration & AC |
Compressor refrigeration capacity | 75.00 kW |
Power consumption | 23.00 kW |
Current draw (460 V) | 37.50 A 1) |
Mass flow | 0.524 kg/s |
at following operating condition:
Refrigerant | R134a |
Reference temperature | Dew point |
Evaporating temperature | 5.0 °C |
Condensing temperature | 50.0 °C |
Supply frequency | 60 Hz |
Voltage | 460 V |
Suction gas temperature | 20 °C |
Subcooling (outside cond.) | 0 K |
Number of cylinders / Bore / Stroke | 6 / 2.76 inch / 2.28 inch |
Displacement 60 Hz (1740 rpm) | 4938 cfh |
Voltage 2) | 440-480V Y/YY -3- 60Hz PW |
Winding divided into | 50% / 50% |
Max. working current 3) | 53.7 A |
Max. power consumption 3) | 38.5 kW |
Starting current (rotor blocked) 3) | 170.0 / 275.0 A |
Motor protection | INT69 G |
Protection terminal box | IP 66 |
Weight | 671 lb |
Frequency range 4) | 25 - 60 Hz |
Max. permissible overpressure (g) (LP/HP) 5) | 276 / 406 psi |
Connection suction line SV | 54 mm - 2 1/8 " |
Connection discharge line DV | 42 mm - 1 5/8 " |
Lubrication | Oil pump |
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 |
Oil charge | 155 fl.oz |
Dimensions
Length / Width / Height | 810 / 557 / 467 mm |
Sound power level LWA 6) | 87 db(A) @ -35 °C / +40 °C |
| 82 db(A) @ -10 °C / +45 °C |
Sound pressure level LpA 6) | 74 db(A) @ -35 °C / +40 °C |
| 68 db(A) @ -10 °C / +45 °C |
Scope of supply
Semi-hermetic six-cylinder reciprocating compressor with
drive motor for part winding start
Single-section compressor housing with
hermetically integrated electric motor
Winding protection with PTC resistor sensors and
electronic trigger unit INT69 G
115-230 V AC, 50/60 Hz,
IP00
Oil pump
Possibility of
connection of oil level controllers ESK, AC+R or CARLY
Possibility of connection of oil level controllers Traxoil 7)
Oil charge:
BOCKlub E55
Sight glass
Internal safety valve
Suction and discharge line valve
Inert gas charge
Accessories
Oil sump heater 110-120 V AC 60 Hz, 160W
Oil pressure safety switch MP54 120/240 V AC/DC, IP20
8)
Oil service valve
Connection piece suction and discharge valve in welding
design
Thermal protection thermostat per cylinder cover
9)
Oil temperature sensor (Pt1000, for external evaluation)
9)
Hot gas temperature sensor (Pt1000, for external
evaluation) 9)
Thermal protection thermostat per cylinder cover
Step protection 8)
Injection nozzle for liquid injection 8)
4 anti-vibration pads enclosed
Special voltage and/or frequency (on request)
Notes
1) | Value calculated. Deviation to reality possible. |
2) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values
PW = part
winding, motors for part winding starting (no start unloaders required)
Designs for Y/D on request |
3) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. |
4) | The maximum permissible working current of the compressor
(Imax) must not be exceeded. Take account of the guidelines for use of frequency
inverter (see compressor assembly instruction or selection software).
|
5) | LP = Low
pressure HP = High pressure |
6) | Declared dual-number noise emission values are in
accordance with ISO 4871. The corresponding uncertainty to the sound power level
is KWA = 2,5 dB and to the sound pressure level is KpA =
2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the
standard rating points according to EN 12900.
- A-weighted sound power level LWA (re 1 pW), in decibel. To
determine the values, measurement methods of the ISO 3740 standard with
accuracy class 2 or higher were used .
- A-weighted sound pressure level LpA (re 20 µPa), in decibel.
The values are calculated from the sound power level in accordance with ISO
11203: LpA = LWA - Q2 at a distance of d = 1m
to the reference box.
|
7) | Only with additional
adapter possible |
8) | Enclosure |
9) | Mounted |