|
|
The value of the following fields was automatically adjusted:
|
HGX12P/75 S 2 LG
|
|
|
 | PDF is being created ... |
 | Loading… |
|
|
For seasonal calculations SI-Units are used (independent of set unit).
|
| |
|
|
 | Loading… |
|
Application
|
 | Loading… |
| Refrigeration & AC |
| Heat Pump |
|
|
| |
|
|
|
|
Power supply
|
 | Loading… |
Hz
 | Loading… |
| 200 |
| 230 |
| 254 |
| 290 |
| 350 |
| 400 |
| 440 |
| 500 |
| 690 |
|
|
| |
|
|
V
|
|
Motor
|
 | Loading… |
| 220-240V Δ / 380-420V Y -3- 50Hz |
| 380-420V Δ / 660-725V Y -3- 50Hz |
|
|
| |
|
|
|
|
Refrigerant
|
 | Loading… |
| R134a |
| R404A, R507 |
| R407C |
| R407F |
| R448A |
| R449A |
| R450A |
| R452A |
| R454C |
| R455A |
| R513A |
| R1234yf |
| R1234ze |
|
|
| |
|
|
|
|
|
Reference temperature
|
 | Loading… |
|
|
Evaporating temperature
|
|
|
Evaporating pressure (abs.)
|
|
|
Condensing temperature
|
|
|
Condensing pressure (abs.)
|
bar
|
|
|
|
|
|
Frequency inverter
|
|
|
Supply frequency
|
|
 | Loading… |
| Suction gas temperature |
| Suction gas superheat |
|
|
| |
|
|
|
|
|
Subcooling (outside cond.)
|
|
|
Usable superheat
|
|
|
|
or individual
|
|
|
|
Compressor refrigeration capacity
|
|
kW
|
|
|
Evaporator refrigeration capacity
|
|
kW
|
|
Power consumption
|
|
kW
|
|
Current draw
(400 V)
|
|
A
|
|
|
|
Coefficient of performance (COP/EER)
|
|
|
|
Condensing capacity
|
|
kW
|
|
Mass flow
|
|
kg/s
|
|
Discharge end temperature
|
|
°C
|
|
|
- Preliminary capacity data.
|
| |
| | |
| | |
|
| Scope of supply and accessories |
|
| Scope of supply and accessories |
|
|
| Dimensions and connections |
|
| Dimensions and connections |
|
| | |
|
| Spare part list, drawings & downloads |
|
| Spare part list, drawings & downloads |
|
| | |
|
|
| |
| |
|
|
Unlimited application range
Supplementary cooling or reduced suction gas temperature (Δtoh<20K)
Compressor operation is possible within the limits shown
on the diagrams of application. Please note the coloured areas. Compressor
application limits should not be chosen for design purposes or continuous
operation. Axis values refer to dew point (saturated vapour line).
|
Number of cylinders / Bore / Stroke |
2 / 38 mm / 34 mm |
|
Displacement 50/60 Hz (1450/1740 ¹/min) |
6,70 / 8,10 m³/h |
|
Voltage |
220-240V Δ / 380-420V Y -3- 50Hz |
|
|
265-290V Δ / 440-480V Y -3- 60Hz |
|
Max. working current |
8.0 / 4.6 A |
|
Max. power consumption |
2.6 kW |
|
Starting current (rotor blocked) |
43.0 / 25.0 A |
|
Motor protection |
INT69 G |
|
Protection terminal box |
IP 66 |
|
Weight |
49 kg |
|
Frequency range |
30 -70 Hz |
|
Max. permissible overpressure (g) (LP/HP) |
19 / 32 bar |
|
Connection suction line SV |
16 mm - 5/8 " |
|
Connection discharge line DV |
12 mm - 1/2 " |
|
Lubrication |
Oil pump |
|
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A |
BOCKlub E55 |
|
Oil type R1234yf, R1234ze, R455A, R454C |
BOCKlub E55; to>15 °C: BOCKlub E85 |
|
Oil charge |
0,8 Ltr. |
|
Dimensions
Length / Width / Height |
412 / 223 / 280 mm |
|
Sound power level LWA |
67 dB(A) @ -35 °C / +40 °C |
|
|
67 dB(A) @ -10 °C / +45 °C |
|
|
66 dB(A) @ +5 °C / +50 °C |
|
Sound pressure level LpA |
55 dB(A) @ -35 °C / +40 °C |
|
|
55 dB(A) @ -10 °C / +45 °C |
|
|
54 dB(A) @ +5 °C / +50 °C |
Semi-hermetic two cylinder reciprocating compressor with
drive motor Single-section compressor housing with hermetically integrated
electric motor |
| Oil pump |
| Winding protection with PTC resistor sensors. Electronic
triggering unit INT69 G to be fitted in switch cupboard (enclosed)
|
| Possibility of
connection of oil level controllers ESK, Traxoil, AC+R or CARLY |
Oil charge: BOCKlub E55 |
| Sight glass |
| Suction and discharge line valve |
| Inert gas charge |
| Dimensioned drawing | display with dimensions and connections |
Format: PDF |
Download |
|
| SV |
Suction line valve, tube ø |
16 mm - 5/8 " |
| DV |
Discharge line valve, tube ø |
12 mm - 1/2 " |
| A |
Connection suction side, not lockable |
1/8 " NPTF |
| A1 |
Connection suction side, lockable |
7/16 " UNF |
| B |
Connection discharge side, not lockable |
1/8 " NPTF |
| B1 |
Connection discharge side, lockable |
7/16 " UNF |
| C |
Connection oil pressure safety switch OIL |
1/8 " NPTF |
| D1 |
Connection oil return from oil separator |
1/4 " NPTF |
| F |
Oil drain |
M 8 |
| H |
Oil charge plug |
1/4 " NPTF |
| I |
Connection hot gas temperature sensor |
1/8 " NPTF |
| J |
Connection oil sump heater |
3/8 " NPTF |
| K |
Sight glass |
1 1/8 " - 18 UNEF |
| L |
Connection thermal protection thermostat |
1/8 " NPTF |
| O |
Connection oil level regulator |
1 1/8 " - 18 UNEF |
| Confirm the license rules | |
|
|
| |
|
|
Technical dataHGX12P/75 S 2 LG | Application | Refrigeration & AC | | Compressor refrigeration capacity | 3.48 kW | | Power consumption | 1.26 kW | | Current draw (400 V) | 2.86 A | | Mass flow | 0.024 kg/s |
at following operating condition: | Refrigerant | R134a | | Reference temperature | Dew point | | Evaporating temperature | 5.0 °C | | Condensing temperature | 50.0 °C | | Supply frequency | 50 Hz | | Voltage | 400 V | | Suction gas temperature | 20 °C | | Subcooling (outside cond.) | 0 K |
| Number of cylinders / Bore / Stroke | 2 / 38 mm / 34 mm | | Displacement 50/60 Hz (1450/1740 ¹/min) | 6,70 / 8,10 m³/h | | Voltage 1) | 220-240V Δ / 380-420V Y -3- 50Hz | | 265-290V Δ / 440-480V Y -3- 60Hz | | Max. working current 2) | 8.0 / 4.6 A | | Max. power consumption 2) | 2.6 kW | | Starting current (rotor blocked) 2) | 43.0 / 25.0 A | | Motor protection | INT69 G | | Protection terminal box | IP 66 | | Weight | 49 kg | | Frequency range 3) | 30 -70 Hz | | Max. permissible overpressure (g) (LP/HP) 4) | 19 / 32 bar | | Connection suction line SV | 16 mm - 5/8 " | | Connection discharge line DV | 12 mm - 1/2 " | | Lubrication | Oil pump | | Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 | | Oil type R1234yf, R1234ze, R455A, R454C | BOCKlub E55; to>15 °C: BOCKlub E85 | | Oil charge | 0,8 Ltr. | | Dimensions
Length / Width / Height | 412 / 223 / 280 mm | | Sound power level LWA 5) | 67 dB(A) @ -35 °C / +40 °C | | 67 dB(A) @ -10 °C / +45 °C | | 66 dB(A) @ +5 °C / +50 °C | | Sound pressure level LpA 5) | 55 dB(A) @ -35 °C / +40 °C | | 55 dB(A) @ -10 °C / +45 °C | | 54 dB(A) @ +5 °C / +50 °C |
Scope of supplySemi-hermetic two cylinder reciprocating compressor with
drive motor Single-section compressor housing with hermetically integrated
electric motor Oil pump Winding protection with PTC resistor sensors. Electronic
triggering unit INT69 G to be fitted in switch cupboard (enclosed)
Possibility of
connection of oil level controllers ESK, Traxoil, AC+R or CARLY 6) Oil charge: BOCKlub E55 Sight glass Suction and discharge line valve Inert gas charge Notes| 1) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values | | 2) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. | | 3) | The maximum permissible working current of the compressor
(Imax) must not be exceeded. Take account of the guidelines for use of frequency
inverter (see compressor assembly instruction or selection software).
| | 4) | LP = Low
pressure HP = High pressure | | 5) | Declared dual-number noise emission values are in
accordance with ISO 4871. The corresponding uncertainty to the sound power level
is KWA = 2,5 dB and to the sound pressure level is KpA =
2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the
standard rating points according to EN 12900.
- A-weighted sound power level LWA (re 1 pW), in decibel. To
determine the values, measurement methods of the ISO 3740 standard with
accuracy class 2 or higher were used .
- A-weighted sound pressure level LpA (re 20 µPa), in decibel.
The values are calculated from the sound power level in accordance with ISO
11203: LpA = LWA - Q2 at a distance of d = 1m
to the reference box.
| | 6) | Only with additional
adapter possible |
|
 | Loading… |
|
Calculation mode
|
|
|
|
Refrigerant
|
 | Loading… |
|
|
|
Reference application
|
|
|
|
Evaporating temperature
|
|
|
|
|
Capacity control
|
|
|
Suction gas temperature
|
°C
|
|
Subcooling (outside cond.)
|
K
|
|
Result
|
Seasonal energy performance ratio
|
|
|
Annual electricity consumption
|
kWh/a
|
Notes
- Calculation considers power consumption of condensers
- Reference temperature: Dew point
|