Two semi-hermetic compressors mounted rigidly next to one another on base
frames and lined with a common suction line connection on the suction side. The
basic compressor:
Semi-hermetic, suction gas-cooled 4-cylinder
reciprocating compressor in compact design. The best possible serviceability is
provided by means of a replaceable drive unit, among other things. The
compressor stands out due to its outstanding running comfort and efficient
operating performance. The suction shut-off valve can be rotated by 90° in each
instance. Dependable mechanism lubrication is guaranteed by means of an oil pump
which is independent of rotating direction, as well as a large-volume oil sump.
The optional oil sump heating is carried out using an immersion sleeve and can
therefore be replaced without intervening in the refrigeration cycle.
An additional connection facility for an oil level regulator is available as
a standard. The electrical connection is simplified by means of a large-volume
electric terminal box. The electronic motor protection MP10 with optical status
indication uses PTC sensors in series to monitor the winding temperature and, if
desired, the discharge gas temperature.
Colour: blue (RAL 5000)
Technical data
DHGX6/1410-4
| f | Qo | Qo' | P | I |
Compressor 1 | 50 Hz | 65.20 kW | 65.20 kW | 21.40 kW | 38.70 A |
Compressor 2 | 50 Hz | 65.20 kW | 65.20 kW | 21.40 kW | 38.70 A |
Total | | 130.40 kW | 130.40 kW | 42.80 kW | 77.40 A |
at following operating condition:
Refrigerant | R134a |
Reference temperature | Dew point |
Evaporating temperature | 5.0 °C |
Condensing temperature | 50.0 °C |
Voltage | 400 V |
Suction gas temperature | 20 °C |
Subcooling (outside cond.) | 0 K |
Number of cylinders / Bore / Stroke | 2 x 4 / 80 mm / 70 mm |
Displacement 50/60 Hz (1450/1740 ¹/min) | 2 x 122,40 / 2 x 146,90 m³/h |
Voltage 1) | 380-420V Y/YY -3- 50Hz PW |
| 440-480V Y/YY -3- 60Hz PW |
Winding divided into | 66% / 33% |
Max. working current 2) | 2 x 65.0 A |
Max. power consumption 2) | 2 x 38.3 kW |
Starting current (rotor blocked) 2) | 2 x 156.0 / 193.0 A |
Motor protection | MP10 |
Protection terminal box | IP 65 |
Weight | 476 kg |
Max. permissible overpressure (g) (LP/HP) 3) | 19 / 28 bar |
Connection suction line SL | 76 mm |
Connection discharge line DV | 2 x 35 mm - 1 3/8 " |
Lubrication | Oil pump |
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 |
Oil type R22 | BOCKlub A46 |
Oil charge | 2 x 3,6 Ltr. |
Oil sump heater | 2 x 230 V - 1 - 50/60 Hz, 2 x 140 W |
Dimensions
Length / Width / Height | 850 / 970 / 505 mm |
Scope of supply
Two semi-hermetic motor compressors HG or HGX (Extent of delivery see compressor) rigidly mounted next to each other on base frame
Oil pump
Ready- mounted with pipes on suction side with joint suction pipe connection
4 rubber plates enclosed
Accessories
Start unloader 230 V - 1 - 50/60 Hz, IP65, less check valve,
including
thermal protection thermostat (posistor tracer)
Start unloader by means of a ESS (Electronic Soft
Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in
switch cabinet 4)
Capacity regulator 230 V - 1 - 50/60 Hz, IP65
1-2 capacity regulator = 75/50/25% residual capacity
Oil sump heater 230 V - 1 - 50/60 Hz, 140 W
Oil service valve
Oil pressure safety switch MP54 230 V - 1 - 50/60 Hz,
IP20 4)
Water-cooled cylinder covers
Oil differential pressure sensor DELTA-P II 220-240 V -
1 - 50/60 Hz 4)
Thermal protection thermostat per cylinder cover
Connection piece suction and discharge valve in welding
design
Sea water resistant water-cooled cylinder covers
Additional fan
230 V AC - 1 - 50 Hz, 97 W,
IP44
230 V AC - 1 - 60 Hz, 128 W 4)
Intermediate adapter for discharge line valve
Special voltage and/or frequency (on request)
Notes
1) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values
PW = part
winding, motors for part winding starting (no start unloaders required)
Designs for Y/D on request |
2) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. |
3) | LP = Low
pressure HP = High pressure |
4) | Enclosure |