Technical data
HGX22e/160 S 3 LG
Application | Refrigeration & AC |
Compressor refrigeration capacity | 5.57 kW |
Power consumption | 2.42 kW |
Current draw (400 V) | 4.94 A |
Mass flow | 0.037 kg/s |
at following operating condition:
Refrigerant | R454C |
Reference temperature | Dew point |
Evaporating temperature | -10.0 °C |
Condensing temperature | 45.0 °C |
Frequency | 50 Hz |
Voltage | 400 V |
Suction gas temperature | 20 °C |
Subcooling (outside cond.) | 0 K |
Number of cylinders / Bore / Stroke | 2 / 50 mm / 40 mm |
Displacement 50/60 Hz (1450/1740 ¹/min) | 13,70 / 16,40 m³/h |
Voltage 1) | 220-240V Δ / 380-420V Y -3- 50Hz |
| 265-290V Δ / 440-480V Y -3- 60Hz |
Max. working current 2) | 13.1 / 7.6 A |
Max. power consumption 2) | 4.4 kW |
Starting current (rotor blocked) 2) | 87.0 / 50.0 A |
Motor protection | INT69 G |
Protection terminal box | IP 66 |
Weight | 75 kg |
Frequency range 3) | 30 -70 Hz |
Max. permissible overpressure (g) (LP/HP) 4) | 19 / 32 bar |
Connection suction line SV | 22 mm - 7/8 " |
Connection discharge line DV | 16 mm - 5/8 " |
Lubrication | Oil pump |
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 |
Oil type R1234yf, R1234ze, R455A, R454C | BOCKlub E55; to>15 °C: BOCKlub E85 |
Oil charge | 1,1 Ltr. |
Dimensions
Length / Width / Height | 468 / 240 / 315 mm |
Sound power level LWA 5) | 69 db(A) @ -35/+40 °C |
| 68 db(A) @ -10/+45 °C |
| 67 db(A) @ +5/+50 °C |
Sound pressure level LpA 5) | 57 db(A) @ -35/+40 °C |
| 56 db(A) @ -10/+45 °C |
| 55 db(A) @ +5/+50 °C |
Scope of supply
Semi-hermetic two cylinder reciprocating compressor with
drive motor
Single-section compressor housing with hermetically integrated
electric motor
Oil pump
Winding protection with PTC resistor sensors. Electronic
triggering unit INT69 G to be fitted in switch cupboard (enclosed)
Possibility of
connection of oil level controllers ESK, Traxoil, AC+R or CARLY 6)
Oil charge:
BOCKlub E55
Sight glass
Suction and discharge line valve
Inert gas charge
Accessories
Compressor oil BOCKlub E85 (factory filling)
7)
Oil sump heater 230 V - 1 - 50/60 Hz, 160
W
Thermal protection thermostat per cylinder cover
8)
Hot gas temperature sensor (Pt1000, for external
evaluation) 8)
Thermal protection thermostat per cylinder cover
Additional fan
230 V AC - 1 - 50 Hz, 97 W,
IP44
230 V AC - 1 - 60 Hz, 128 W 9)
4 anti-vibration pads enclosed
Special voltage and/or frequency (on request)
Notes
1) | Tolerance (± 10%)
relates to the mean value of the voltage range. Other voltages and current types
on request
All data are based on voltage rms values |
2) | - The stated value for the max. power consumption is valid
for the adjusted power supply.
- Starting current (rotor blocked):
- Part winding (PW) motors: Winding 1 / Winding 1+2
- Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max.
operating current / max. power consumption for designing motor contractors, feed
lines, fuses and motor protection switches. Motor contractors: Consumption
category AC3. |
3) | The maximum permissible working current of the compressor
(Imax) must not be exceeded. Take account of the guidelines for use of frequency
inverter (see compressor assembly instruction or selection software).
|
4) | LP = Low
pressure HP = High pressure |
5) | Declared dual-number noise emission values are in
accordance with ISO 4871. The corresponding uncertainty to the sound power level
is KWA = 2,5 dB and to the sound pressure level is KpA =
2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the
standard rating points according to EN 12900.
- A-weighted sound power level LWA (re 1 pW), in decibel. To
determine the values, measurement methods of the ISO 3740 standard with
accuracy class 2 or higher were used .
- A-weighted sound pressure level LpA (re 20 µPa), in decibel.
The values are calculated from the sound power level in accordance with ISO
11203: LpA = LWA - Q2 at a distance of d = 1m
to the reference box.
|
6) | Only with additional
adapter possible |
7) | from to>15°C for R1234yf/R1234ze |
8) | Mounted |
9) | Enclosure |