Technical data
FKX40/390 TK
Application | Refrigeration & AC |
Compressor refrigeration capacity | 16.70 kW |
Drive power | 6.79 kW |
Torque | 44.80 Nm |
Mass flow | 0.138 kg/s |
at following operating condition:
Refrigerant | R404A, R507 |
Reference temperature | Dew point |
Evaporating temperature | -10.0 °C |
Condensing temperature | 45.0 °C |
Speed | 1450 1/min |
Suction gas temperature | 20 °C |
Subcooling (outside cond.) | 0 K |
Number of cylinders / Bore / Stroke | 4 / 50 mm / 49 mm |
Swept volume | 385 cm³ |
Displacement (500/1450/2600 rpm) | 11,50 / 33,50 / 60,00 m³/h |
Mass moment of inertia | 0,0043 kgm² |
Weight | 34 kg |
Permissible range of rotation speeds | 500 - 2600 ¹/min |
Max. permissible overpressure (g) (LP/HP) 1) | 19 / 28 bar |
Connection suction line SV | 28 mm - 1 1/8 " |
Connection discharge line DV | 22 mm - 7/8 " |
Lubrication | Oil pump |
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A | BOCKlub E55 |
Oil charge | 2,0 Ltr. |
Dimensions
Length / Width / Height | 384 / 320 / 369 mm |
Scope of supply
Open piston
compressor in a light alumininium construction,
with suction and discharge
valves
Oil pump
Four cylinder,
cylinder arrangement in V
Seat front bearing
flange
Integrated oil collecting system for the shaft seal with
leak oil drain hose
Fastening possibility for electromagnetic clutch
TK Design
Oil charge:
BOCKlub E55
Two sight
glasses
Pressure relief valve
Inert gas charge
Accessories
Capacity regulator 24 V DC, IP65
1 capacity regulator =
50% residual capacity
Electromagnetic clutch 24 V DC LA 16, power consumption
39W 2)
Flywheel:
Outer diameter: 210 [mm]
V-belt profile: SPA DIN 7753
Number of grooves: 3
Weight: 11.6 [kg] 3)
Oil sump heater 24 V
DC, 80 W
Thermal protection thermostat (bimetal tracer)
Parts for shaft end
Intermediate flange for changing the position of the
shut-off valves.
Oval flange, height 5 / 12 / 15 /
25 / 27 / 34 / 46 / 57,5 / 62 / 71 / 75
or 95 mm.
Heights are partially subject to restrictions regarding valve
type and orientation. 4)
Notes
1) | LP = Low
pressure HP = High pressure |
2) | Other voltages / designs on request |
3) | Enclosure |
4) | Other designs on request |